Basic Info.
Test Range
0.1-300 Micron
Application
Cement, Flour, Ceramics, Medicament, Mine
Accuracy Error
<1% (Deviation of D50 on National Standard Sample)
Repeatability Error
<1% (Deviation of D50 on National Standard Sample)
Dispersion
Dry-Turbulence Dispersion Mode
Product Name
Dry Dispersion Soil Analysis Powder Equipment
Transport Package
Plywood Box
Specification
L88*W40*H30cm
Product Description
Dry Dispersion Soil Analysis Powder Equipment
for Soil Particle Size Testing
Brief introduction:
Winner3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Main Specifications:
Model Name | Winner3003 |
Size Range | 0.1-300μm |
Standard | ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013 |
Channels Number | 40 pcs |
Accuracy | <1% (Deviation of D50 on national standardsample) |
Repeatability | <1% (Deviation of D50 on national standard sample ) |
Light Source | He-Ne laser (λ= 632.8nm, P>2.0MW) |
Dispersion Method | Dry-turbulence dispersion mode |
Operation Mode | Manual/Automatic |
Optical Path CalibrationSystem | Automatic |
Dispersing Medium | Compressed air |
Test Speed | <1min for each time |
Operation System | Win XP/ Win 7 |
Connection Port | USB |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification |
Statistic Method | Volume Distribution, Quantity Distribution |
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries. |
Test Report | Word, Excel,Photo( Bmp), Text etc |
Multi-language Support | Chinese&English |
Intelligent Operation Mode | Automatically control Air flow speed, dispersion,test and analysis.Better Repeatability after remove human-factor |
Volume | L88cm×W40cm×H30cm |
Net Weight | 36Kg |
Main Features:
1) Unique patent technology of optical path and detection system, greatly improve testing resolution.
Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.
2)Scientific and automatic dry dispersing system
Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system's working life but ensure more accurate and stable testing result.
3)Intelligent Operation System realize one key test
Just need put in sample, Dust collection, air supply,feeding and others are all automatic. It only only reduces workload, but eliminate errors caused by human factors, further improve testing accuracy and authenticity of the testing results.
4)Software support
Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.
Related Products:
Principle:
Application:
Winner3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique applicability and practicality.
Standard Accessories:
Our Served Industry
Company Picture
Our Patent:
We have CE and ISO9001 :
Please Contact Us :
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.