Basic Info.
Sample Feeding
Dry Dispersion
Measuring Theory
Laser Diffraction
Measuring Range
Dry 0.1-2000um
Dispersion System
Dry Dispersion System
Output Parameter
D10 D50 D90 D[3, 2] D[4, 3]
Dispersion Method
Dry-Turbulence Dispersion Mode
Application
Pharmaceutical Powders, Ceramic Powders
Dispersion Source
Compressed Air
Statistic Method
Volume Distribution, Quantity Distribution
Optical Alignment
Automatic
Transport Package
Plywood Box
Specification
L23*W64*H66cm
Product Description
Winner3008 Intelligent Dry Dispersion Laser Particle Size Analyzer
Brief Introduction:
Winner3008A is intelligent laser particle size analyzer with dry dispersion unit, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.It use air as dispersion medium, and use turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability. Main Specifications:
Model | Winner3008A |
Standard | ISO 13320-1:1999;GB/T19077.1-2308;Q/0100JWN001-2013 |
Measuring Range | 0.1μm-2000μm |
Photoelectric probe | 100 |
Accuracy error | <1% (Deviation of D50 on national standard sample) |
Repeatability error | <1% (Deviation of D50 on national standard sample ) |
Light source | He-Ne laser (λ= 632.8nm, P>2.0MW) |
Dispersion | Dry-turbulence dispersion mode, normal shock wave shear technique |
Operation Mode | Manual & Full automatic |
Operation temperature | +5°C to +40°C |
Feeding | Automatic vibration feeding |
Optical Calibration System | Automatic |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
Statistic Method | Volume Distribution, Quantity Distribution |
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries |
Test Report | Word, Excel,Photo( Bmp), Text etc |
Multi-language Support | Multi-language Support |
Intelligent operation | Better Repeatability after remove human-factor |
Test Speed | <1min for each time |
Power supply | 220V |
Outer dimension | L105cm×W44cm×H54cm |
Net Weight | 58Kg |
Main Features:
1) Advanced testing optical path.Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Dual spectrum plane optical design, rational distribution of 100 Photoelectric probe, effectively collecting the light intensity of forward, side direction three-dimensional space, the minimum detection angle is up to 0.0155 degrees, to expand the measurement range to 2000 microns, imported from Japan Fourier lens, to ensure stable and accurate particle sizing. 2)Scientific dispersion systemTurbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system's working life.3)Human-based operation modeManual and Full automatic, easy choose. 4)High precision-automatic optical path calibration systemIt's composed of precise four phase hybrid stepper motor, Its inching precision is reach to 0.1 micron level, so light path is always in a good state.5)Intelligent data analysis-winner unique software supportAnalysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output. The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).
Users can design the test report output and display forms according to industry requirements.
4. Application:Winner3008 is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive, pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin,coffee and other powder materials. It has unique applicability and practicability, especially for those occurs chemical reactions, change shapes and loss in liquid, such as Chinese herbal medicine, magnetic materials and powder industry with wide distribution and large particle size. 5. Standard Accessories List: NO. | Items | Quantity | Unit | Remark |
1 | Winner 3008 Laser particle size analyzer | 1 | Set | |
2 | Software | 1 | Set | |
3 | Dongel | 1 | PCS | |
4 | Air compressor | 1 | PCS | |
5 | Dust cleaner | 1 | PCS | |
6 | Emery | 1 | PCS | |
7 | Power cable | 2 | PCS | |
8 | Communication cable | 1 | PCS | |
9 | Negative pressure gauge | 1 | PCS | |
10 | Screw driver | 3 | Set | |
11 | Wrench | 2 | PCS | |
12 | Balloon | 1 | PCS | |
13 | Brush | 1 | PCS | |
14 | Cleaning mirror paper | 3 | PCS | |
15 | PU pipe Φ8 | 1 | PCS | |
16 | Silicone tube | 1 | PCS | |
17 | Spoon | 1 | PCS | |
18 | 2A fuse | 5 | PCS | |
19 | Quality certificate | 1 | PCS | |
20 | Warranty Card | 1 | PCS | |
21 | Manual | 1 | PCS | |
6. Patents Technology:
Winner 3008 Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
Optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
Comany Information:
Winner Particle Instrument Stock Co.,Ltd. have been specialized in laser particle size analyzer since 1985, as the leading manufacturer in China, winner undertake the national science and technology project for many times, get more than 30 patents technology, Strongly recommended by 500 Universities in China!
1st Circulation test wet particle size analyzer
1st Dry particle size analyzer
1st Dynamic particle image instrument
1st Nano particle size analyzer
1st Image laser particle size analyzer
1st Inline particle size analyzer
Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!
FAQPurchase laser particle size analyzer need know points:
1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also.
Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.
For dry dispersion model, just use compressed air as dispersion media.
In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.