Basic Info.
Measuring Theory
Laser Diffraction
Measuring Range
0.01 -1000 Um
Dispersion System
Wet Dispersion
Light Source
He-Ne Laser & Semiconductor
Measusring Sample
Emulsion, Powders and Suspension
Accuracy Error
<1%(Deviation of D50 on National Standard Samples)
Repeatability Error
<1%(Deviation of D50 on National Standard Samples)
Test Speed
<2min Per Time
Measurement Principle
Mie Scattering Principle
Operation Mode
Manual and Full Automatic Software Control
Product Name
Wet Dispersion Laser Particle Size Analyzer for Ca
Transport Package
Plywood Box
Specification
L85*W39*H45cm
Product Description
Famous Brand Winner2005A Fraunhofer diffraction and Mie scattering theory basis laser particle size analyzer
Brief Introduction: Winner2005 intelligent full automatic laser particle size analyzer. It enables you understand materials well, such as painting,dyes, minerals power, calcium carbonate, kaolin, water-coal-slurry Photosensitive material,Medicine and Metal oxide etc. Industry.Unique Advantage:- Double Laser Orthogonal beam patent technology
- Unique sample cell for sub-micron materials particle size distribution test, test limit is 0.01um.
- Unconstrained free fitting analysis software, Particle size analysis is not limited by any function, reflected real particle size distribution.
- Calibration by China certified reference materials D50 value, accuracy and repeatability is up to 0.5%.
- Simple operation, one key done, easy work for you!
Application: 1. Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite,clay, garnet, vermiculite, Titanium white power, etc.
2. Metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.
3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, pigment, oil exploration, geological analysis, river silt and electronic particle, etc.Main Specifications: Model Name | Winner2005A | Winner2005B |
Standard | ISO13320:2009,GB/T19077-2016,Q/0100JWN001-2013 |
Size range | 0.01-1000μm | 0.1-1000μm |
Channels | 90 | 87 |
Accuracy error | <0.5% (Deviation of D50 on national standard sample) |
Repeatability error | <0.5% (Deviation of D50 on national standard sample) |
Laser | He-Ne Laser λ= 636.5nm, p>2mW Auxiliary Laser: semiconductor λ= 532nm,p:1-40mW |
Wet dispersion | Ultrasonic | Frequency:40KHz Power:60W, Time: ≥1S |
Agitator | Revolutions Speed: 0-3000RPM (Adjustable) |
Circulation | Rated Flow:17L/min Rated Power:15W |
Sample pool | Volume: 450mL |
Operation mode | Manual and Full automatic |
Optical alignment system | Full automatic optical path alignment system |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
Statistic Method | Volume Distribution, Quantity Distribution |
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries |
Test Report | Word, Excel,Photo( Bmp), Text etc |
Multi-language Support | Multi-language Support |
Intelligent operation | Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor |
Testing speed | <2min/time |
Outer dimension | L85cm*W39cm*H45cm |
Net weight | 40Kg |
Main Features:1) Optical light system: Adopt orthogonal double laser beam patented technology, measure range expanded from 0.01 to 1000μm. 2)Intelligent operation mode realize one key test, automatically draw water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors. 3) Optical light Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.. 4)Sample dispersion system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.
5)Software support: Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
Ralated products
Packaging & Shipping
Our Services
Quality Assurance For Laser Particle Size Analyzer
1. Strictly conforming to ISO9001-2000 quality management system,
2. Strict control from purchasing materials, process inspection to final particle size distribution test,
3. QC department to execute quality control regulations,
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5, Laser particle size analyzer will be processed preventing -shake test before delivery.
After sale service
1. We will send our technician to install the laser particle size analyzer if customer need.( operation demo video CD will be offered also.)
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Certificates
Company informationExhibitionOur customersContact me
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.