Basic Info.
Measuring Theory
Laser Diffraction
Measuring Range
0.01 Micron-1200 Micron
Dispersion System
Wet Dispersion
Accuracy Error
<1%(Crm D50)
Repeatability Error
<1%(Crm D50)
Circulation Rated Flow
30L/Min
Revolutions Speed
0-3000 Rpm
Operation Mode
Digital Display
Transport Package
Plywood Box
Specification
L104*W440*H540mm
Product Description
Winner2008B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μmto 2000 μm Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.
Main Specifications:
Model Name | Winner2008A | Winner2008B |
Standard | ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 |
Principle | MIE scattering principle |
Measuring Range | 0.01μm-2000μm | 0.01μm-1200μm |
Channels Number | 127 | 120 |
Accuracy error | <1% (Deviation of D50 on national standard sample) |
Repeatability error | <1% (Deviation of D50 on national standard sample ) |
Light source | High performance He-Ne Laser (λ= 632.8nm, P>2MW) Lifetime>25000hours |
Dispersion Method | Ultrasonic | Frequency:40KHz Power:35W, Time: ≥1S |
Stir | Revolutions Speed: 0-300RPM (Adjustable) |
Circulate | Rated Flow:8L/min Rated Power:10W |
Sample Pool | Volume:1000mL |
Micro- Sample Pool | Volume: 10mL ( Available) |
Operation Mode | Full automatic/ manual control, freely choose |
Optical bench alignment system | Full automatic,precision is up to 0.1um |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
Statistic Method | Volume Distribution, Quantity Distribution |
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries |
Test Report | Word, Excel,Photo( Bmp), Text etc |
Multiple-language Support | Multiple language Support |
Intelligent operation | Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor |
Testing speed | <2min/time |
Outer dimension | L66cm*W32cm*H40cm |
Net weight | 65Kg |
Main Features: 1)Winner Patent -Optical path design
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01μm to 2000μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals.
2) Expand Size Range
Winner2008A measurement range significantly expanded to 0.01μm, particularly suitable for small samples of the user, the sub micron particle test results reached the international level
3)Full built-in dispersion system
The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.
4)Intelligent Operation mode
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.
5)Automatic Optical path alignment system
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.
6)Authoritative calibration method
In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.
7) Unconstrained free fitting technique
Winner original unconstrained free fitting technology, particle size analysis is not affected by any functional constraints, can be a true reflection of the distribution of particles.
Instrument principle diagram Adopt Patents Technology: 1.Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
2.Optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
3.Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
4.Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
Instrument Test operation interface: After the background test, click on Energy spectrum test" in "test view". And the system will display "test view". Observe the Spectral curve and concentration, After the test result becomes stable, click the "save the results". The System will automatically save the test result at the preset time intervals
Energy Spectrum Test View
Test Report and Its Description: 1) D10 : Particle diameter, < 10% particle volume summation percent of total particle's volume
2) D50 : Particle diameter, < 10% particle volume summation percent of total particle's volume
3) D90 : Particle diameter, < 10% particle volume summation percent of total particle's volume
4) DAV:The average particle size of the particle swarm
5) S/V: Volume specific surface area; surface area per unit volume of particles
Particle size analysis diagram:
1)Horizontal axis is the size of the particle, which is the logarithm distribution.
2)Left column is the volume of the cumulative percentage, corresponding to the upward trend curve
3)Right column is the volume percentage of a certain interval, corresponding to the histogram or the ups and downs of the curve.
4)The test result of data list is corresponding to the analysis chart.
Application: Winner2008 is widely used in mineral materials, cement, ceramics, chemicals, paint, emulsion, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasive, lubricant, coal, sand, dust, bacteria, cells, food, additives, pesticides, explosives, graphite, photosensitive materials, fuel, and ink metal and non metal powder, calcium carbonate, kaolin, coal water slurry and other powder material.
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.