Basic Info.
Warranty
One Year Warranty From Installation
Measurement Range
0.1-300 Micron
Measusring Sample
Emulsion, Powders and Suspension
Accuracy Error
<0.5% Reference to Crm D50
Repeatability Error
<0.5% Reference to Crm D50
Method
Full Mie Scattering Theory
Built in Dispersion
Full Automatic Ultrasonic, Agitator, Circulation a
Operation
Intelligent Computer Control
Operation Mode
Manual and Full Automatic
Transport Package
Plywood Box
Product Description
CE approved Winner2000ZDE Liquid dispersion Laser diffraction Particle Size Analyzer with nice price
- Overview:
Winner2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
- Main Specifications:
Model Name | Winner2000ZDE |
Standard | ISO13320:2009, GB/T19077-2016, Q/0100JWN001-2013 |
Principle | MIE scattering principle |
Measuring Range | 0.1-300μm |
Channels Number | 78 |
Accuracy error | <0.5% ( CRM D50 ) |
Repeatability error | <0.5% ( CRM D50 ) |
Light source | High performance He-Ne Laser (λ= 632.8nm, P>2MW) Lifetime>25000hour |
Dispersion Method | Ultrasonic | Frequency:40KHz Power:60W, Time: ≥1S |
Stir | Revolutions Speed: 0-3000RPM (Adjustable) |
Circulate | Rated Flow:8L/min Rated Power:10W |
Sample Pool | Volume:350mL |
Micro- Sample Pool | Volume: 10mL ( Available) |
Operation Mode | Full automatic and manual |
Output parameter | D10,D50,D90,D100,S/V referent parameters |
Optical Calibration System | Full automatic |
Test Speed | <2mins for each time |
Dimension | L88cm×W39cm×H46cm |
Net Weight | 41Kg |
2. Main Features:
1,Advanced design of light path:
A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument, and ring shaped of multi-element silicon photo-diode ensure gathering all the light signals of particles, highly improve the resolution.
2,Built-in dispersion units:
We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.
3,Unconstrained fitting techniques:
The particle analysis software uses a unique unconstrained data fitting technique that we developed to obtain data of real particle size distribution, this is particularly important for researchers.
4,Micro sample chamber (optional):
The capacity of the sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.
5,Modern measurement control:(Intelligent SOP Operation)
Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.
6,User-friendly Operation:
manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.
7,Fully automatic light path alignment:
A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment, precision is up to 0.1um, This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.
8,Quick measurements:
set " automatic" mode, all operation procedures are performed automatically,automatic water supply, automatic ultrasonic sample, stirring, circulation,background testing, sample testing,analysis , draining and cleaning, which significantly reduces the time for measurements, the full process only take 2 minutes.
9,Data analysis:
Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard.
3. Software Function
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
2,Statistic Method
Volume Distribution, Quantity Distribution
3,Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
4,User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
5,Test Report
Word, Excel,Photo( Bmp), Text etc.
6,Multiple language Support
Chinese&English (Others are available)
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
4. Laser Particle Size Analyzer Application Field:
1.Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite,clay, garnet, vermiculite, Titanium white power, etc.
2. Metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.
3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, toner,pigment, oil exploration, geological analysis, river silt and electronic particle, etc.
5. Winner2000ZDE Laser Particle Size Analyzer Patents Technology:- Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
- Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
- MIE scattering principle application patent is protected by patent No.- ZL 2013 2 0812021.4.
- Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.
Working Principle
Packaging&Shipping
Our Services
Quality Assurance For Laser Particle Size Analyzer
1. Strictly conforming to ISO9001-2000 quality management system,
2. Strict control from purchasing materials, process inspection to final particle size distribution test,
3. QC department to execute quality control regulations,
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5, Laser particle size analyzer will be processed preventing -shake test before delivery.
After sale service
1. We will send our technician to install the laser particle size analyzer if customer need.( operation demo video CD will be offered also.)
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Certificates
Company information
All of our Particle size analyzer is approved by CE and ISO Certification. Winner also get the certification of National High-Tech Enterprise, "Winner" Brand Registation ,Software copyright, and machine design patent, etc.
Our factory is based in Jinan, China, We are the manufacturer for 30 years, and has been the leading enterprise in China all the time. All material is of high quality under inspection and control,and all the particle size analyzer go through 2 times of test before shipment.
High quality assurance is our task and also what we are doing now.
Related products:
Exhibitions
Our Customers
Contact us
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.