Basic Info.
Measuring Theory
Laser Diffraction
Measuring Range
Wet 0.01um-2000um Dry 0.1-2000um
Dispersion System
Automatic Dry Wet Dispersion
Output Parameter
D10-D100, Specific Surface Area
Circulation Rated Flow
8L/Min
Revolutions Speed
0-3000 Rpm
Operation Mode
Intelligent Full Automatic Sop
Optical Alignment System
Automatical
Transport Package
Plywood Box
Specification
L123*W65*H69cm
Product Description
Winner2308A Intelligent Wet and Dry Laser Particle Size Analyzer
Overview:
Winner2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.01μm to 2000μm(dry 0.1μm-2000μm), Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It's the prior choice for industrial production quality control departments and research institutions.
Main Specifications: Model Name | Winner2308A |
Standard | ISO 13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013 Compliance with 21 CFR Part 11 |
Principle | Laser diffraction principle |
Analysis | Mie and Fraunhofer scattering |
Detector Arrangement | Log-spaced array, test angle from 0.015 degree to 145 degree |
Measuring Range | Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm |
Channels Number | Wet:127 pcs Dry:127 pcs |
Accuracy error | Wet<1% Dry<1% (CRM D50) |
Repeatability error | Wet<1% Dry<1% (CRM D50) |
Light source | Dual lens, He-Ne laser P>3.0 MW (λ= 632.8nm) Auxiliary green semiconductor laser (λ= 532.8 nm) P>2.0MW , |
Laser Safety | Class 1 |
Wet dispersion | Ultrasonic | Frequency:40KHz Power:60W, Time: ≥1S |
Stir | Revolutions Speed: 0-3000RPM (Adjustable) |
Circulate | Rated Flow:30L/min Rated Power:70W |
Sample tank | Volume:1000mL |
Micro- Sample cuvette | Volume: 10mL ( Available) |
Dry dispersion | Dry-turbulence dispersion patent, normal shock wave shear technique |
Feeding Speed | Adjustable (Variable speed knob) |
Operation Mode | Full automatic / manual control, freely choose |
Dispersion medium | Compressed Air, pressure: 0 to 6 bar |
Optical bench alignment system | Full automatic, precision is up to 0.2um |
Test Speed per time | Wet: <2 Min Dry : <1min Typical measuring time<10S |
Outer dimension | L104cm×W44cm×H54cm |
Net Weight | 70Kg |
Main Features:
1)Wet and dry sample dispersion system Integrated Design
Winner2308 intelligent laser particle size analyzer which is 1st set laser particle size analyzer integrated wet and dry dispersion test in one in China, it successfully resolved the problem of dry and wet technology integration, realize one key to switch, apply to test all the particle size distribution of powders, emulsion and suspension.
2) Intelligent full automatic operation system and manual operation mode, freely choose.
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all process will be complete automatically,
not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.
Wet method: A key to complete water-supply, ultrasonic dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, only take 2 mins.
Dry method: A key to complete the dust collecting, air supply, feeding, testing, data processing and other operation, take 1 min.
3) Stable and unique optical path system patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and Dual-laser orthogonal light technology make use of the semiconductor auxiliary laser extend the test angle from 0.015 degree to 145 degree, ensure receive all the angles of signals.
4) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.
5) Full built-in Sample dispersion system.
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.
For dry dispersion system, Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion,ensure good test.
6)Instrument Software
Original Unconstrained free fitting patent technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles size distribution, The instrument provide high precision data with
10Khz data acquisition time.
Adopt unconstrained free fitting patent
technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.
4. Software Function:
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
2,Statistic Method
Volume Distribution, Quantity Distribution
3,Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
4,User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
5,Test Report
Word, Excel,Photo( Bmp), Text etc.
6,Multiple language Support
Chinese&English (Others are available)
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
Figure-Winner2308 laser particle size analyzer scheme
5.Application:
Winner2308 widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.
6.Adopt Patents Technology: Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2
Comany Information:
Winner Particle Instrument Stock Co.,Ltd. have been specialized in laser particle size analyzer since 1985, as the leading manufacturer in China, winner undertake the national science and technology project for many times, get more than 30 patents technology, Strongly recommended by 500 Universities in China!
1st Circulation test wet particle size analyzer
1st Dry particle size analyzer
1st Dynamic particle image instrument
1st Nano particle size analyzer
1st Image laser particle size analyzer
1st Inline particle size analyzer
Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!
FAQPurchase laser particle size analyzer need know points:
1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also.
Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.
For dry dispersion model, just use compressed air as dispersion media.
In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.